Requested revision
Standard:802.1QbgClause:12, 17
Clause title:Management protocol
Rationale for revision
Clause 12 specifies object called evbSysEcpDfltAckTimerInit and evbSysEcpDfltMaxTries. however clause 17 references objects by the names ieee8021BridgeEvbSysEcpAckTimer and ieee8021BridgeEvbSysEcpMaxTries in table 17-26 and ieee8021BridgeEvbSysEcpMaxRetries in the MIB text. These names should be alligned and MaxTries should be relaced with MaxRetries.
Proposed text
Replace evbSysEcpDftlMaxTries in clause 12 and table 12-17 with evbSysEcpDfltMaxRetries. Replace ieee8021BridgeEvbSysEcpAckTimer and ieee8021BridgeEvbSysEcpMaxTries in table 17-26 with ieee8021BridgeEvbSysEcpDfltAckTimerInit and ieee8021BridgeEvbSysEcpDfltMaxRetries. Deprecate ieee8021BridgeEvbSysEcpAckTimer and ieee8021BridgeEvbSysEcpMaxRetries from the SNMP MIB and add new replacement objects called ieee8021BridgeEvbSysEcpDfltAckTimerInit and ieee8021BridgeEvbSysEcpDfltMaxRetries.
Impact on existing networks
<replace this text with a description of impact on existing networks>
Originator
Name:Paul BottorffEmail:paul.bottorff@hp.com
Affiliation:Hewlett-Packard