802.1 Tools
  • Home
  • Maintenance
    • All items
    • Open items
    • Closed items
    • Items for review
    • Status
  • Meetings
  • Help
  • Log in
Requested revision
Standard:802.1Q-2012Clause:17.7.6
Clause title:Definitions for the IEEE8021-MSTP MIB module
Rationale for revision
The DESCRIPTION of ieee8021MstpVlanV2Table says "In an MSTP Bridge, the fixed-length (4096 elements), read-only, MST Configuration Table..." ieee8021MstpVlanV2Table added 0 & 4095 to the range of ieee8021MstpVlanV2MstId for 802.1aq, but it is indexed by IEEE8021VlanIndex, which is Unsigned32 (1..4094|4096..4294967295), and its MIB description states that “values of 0 and 4095 are not permitted”.
Proposed text
Change the DESCRIPTION of ieee8021MstpVlanV2Table to "In an MSTP Bridge, the fixed-length (4094 elements), read-only, MST Configuration Table."
Impact on existing networks
Originator
Name:Raphael GartiEmail:raphael_g@rad.com
Affiliation:RAD Data Communications Ltd.
Submitted:2013-03-28