Requested revision
Standard: | 802.1Q-2012 | Clause: | 17.7.6 |
Clause title: | Definitions for the IEEE8021-MSTP MIB module |
Rationale for revision
The DESCRIPTION of ieee8021MstpVlanV2Table says "In an MSTP Bridge, the fixed-length (4096 elements), read-only, MST Configuration Table..." ieee8021MstpVlanV2Table added 0 & 4095 to the range of ieee8021MstpVlanV2MstId for 802.1aq, but it is indexed by IEEE8021VlanIndex, which is Unsigned32 (1..4094|4096..4294967295), and its MIB description states that “values of 0 and 4095 are not permitted”.
Proposed text
Change the DESCRIPTION of ieee8021MstpVlanV2Table to "In an MSTP Bridge, the fixed-length (4094 elements), read-only, MST Configuration Table."
Impact on existing networks
Originator
Name: | Raphael Garti | Email: | raphael_g@rad.com |
Affiliation: | RAD Data Communications Ltd. | ||
Submitted: | 2013-03-28 |