Requested revision
Standard: | 802.1Qbu-2016 | Clause: | 17.7.22 |
Clause title: | Definitions for the IEEE8021-ST-MIB module |
Rationale for revision
The MIB will not compile because on page 27 both OBJECT-TYPEs ieee8021STMaxSDU and ieee8021TransmissionOverrun are defined with "::= { ieee8021STMaxSDUEntry 2}".
Proposed text
In ieee8021TransmissionOverrun OBJECT-TYPE change "::= { ieee8021STMaxSDUEntry 2}" to "::= { ieee8021STMaxSDUEntry 3}". Note: this fix was published in 802.1Qbv-2016, page 39. Also see comment #56 in http://www.ieee802.org/1/files/private/q-REV-drafts/d1/802-1Q-rev-d1-1-dis-v1.pdf.
Impact on existing networks
I suspect there will be no impact since no one would have been able to use the existing 802.1Qbu-2016 MIB because it would not compile.
Originator
Name: | Craig Gunther | Email: | craig.gunther@harman.com |
Affiliation: | Harman International | ||
Submitted: | 2017-02-07 |