Requested revision
| Standard: | 802.1Qbu-2016 | Clause: | 17.7.22 | 
| Clause title: | Definitions for the IEEE8021-ST-MIB module | ||
Rationale for revision
The MIB will not compile because on page 27 both OBJECT-TYPEs ieee8021STMaxSDU and ieee8021TransmissionOverrun are defined with "::= { ieee8021STMaxSDUEntry 2}".Proposed text
In ieee8021TransmissionOverrun OBJECT-TYPE change "::= { ieee8021STMaxSDUEntry 2}" to "::= { ieee8021STMaxSDUEntry 3}".
Note: this fix was published in 802.1Qbv-2016, page 39.
Also see comment #56 in http://www.ieee802.org/1/files/private/q-REV-drafts/d1/802-1Q-rev-d1-1-dis-v1.pdf.Impact on existing networks
I suspect there will be no impact since no one would have been able to use the existing 802.1Qbu-2016 MIB because it would not compile.
    Originator
| Name: | Craig Gunther | Email: | craig.gunther@harman.com | 
| Affiliation: | Harman International | ||
| Submitted: | 2017-02-07 | ||