  2. 0217
  3. Request
Requested revision
Standard:802.1Qcp-2018Clause:48.6.3.3
Clause title:Definition for the ieee802-dot1q-bridge YANG module
Rationale for revision
Only static/managed entries are configurable filtering entries by
the user (e.g., NETCONF client). The existing model does not prevent
a user from trying to add/modify/edit a dynamic entry which is a
violation.
Proposed text
The filtering entries model should be broken out in to 'config true'
and 'config false' containers, where only static entry information is
found within the 'config true' container. The 'config false' container
can include data associated with both dynamic and static entries.
Impact on existing networks
YANG upgrade on 'ieee802-dot1q-bridge.yang' will be required.
Originator
Name:William ZhaoEmail:william.zhao@siemens.com
Affiliation:Siemens
Submitted:2018-09-25