802.1 Tools
  • Home
  • Maintenance
    • All items
    • Open items
    • Closed items
    • Items for review
    • Status
  • Meetings
  • Help
  • Log in
Requested revision
Standard:802.1Q-2018Clause:12.29.1.2.1
Clause title:GateControlEntry
Rationale for revision
The gateStatesValue and timeIntervalValue are always present in a GateControlEntry. The "if present" language is incorrect. See this email for details: http://www.ieee802.org/1/private/email2/msg30497.html Note that: 1. Table 8-7 in Q came from Table 8-6 in Qbv/D1.3, 2. Clause 12.29.1.2.1 in Q came from 12.28.1.2.1 in Qbv/D1.3,
Proposed text
Remove ", if present," text in both places in 12.29.1.2.1 GateControlEntry since the associated gateStatesValue and timeIntervalValue parameters are always present.
Impact on existing networks
There is no impact since there is no case where the parameters are not present.
Originator
Name:Craig GuntherEmail:craiggunther@yahoo.com
Affiliation:Craig Gunther Consulting
Submitted:2020-05-19