  1. Maintenance Items
  2. 0268
  3. Request
Requested revision
Standard:IEEE 802.1Q-2018Clause:17.7.14 and 17.7.22
Clause title:Definitions for the IEEE8021-SRP-MIB module and Definitions for the IEEE8021-ST-MIB module
Rationale for revision
IEEE8021-SRP-MIB does not fully comply with SMIv2 (see RFC 2578).

According to SMIv2:

- table index objects shall be defined with MAX-ACCESS value "not-accessible", and

- table index objects must not be members of GROUPs.



IEEE8021-ST-MIB with copy-and-paste typo.
Proposed text
(1) IEEE8021-SRP-MIB:

ieee8021SrpReservationPreloadDirection OBJECT-TYPE

SYNTAX IEEE8021SrpReservationDirectionValue

MAX-ACCESS read-write not-accessible

...



(2) IEEE8021-SRP-MIB:

ieee8021SrpReservationsPreloadGroup OBJECT-GROUP

OBJECTS {

ieee8021SrpReservationsPreloadStreamId,

ieee8021SrpReservationPreloadDirection,

ieee8021SrpReservationPreloadAccumulatedLatency

}

...



(3) IEEE8021-SRP-MIB:

ieee8021SrpStreamsPreloadGroup OBJECT-GROUP

OBJECTS {

ieee8021SrpStreamPreloadId,

ieee8021SrpStreamPreloadDestinationAddress,

...

}



(4) IEEE8021-ST-MIB:

-- =============================================================

-- IEEE8021 FQTSS ST MIB - Conformance Information

-- =============================================================
Impact on existing networks
None - table index objects cannot be accessed by SNMP get/put operation, - typo is in a comment section.
Originator
Name:Josef DorrEmail:josef.dorr@siemens.com
Affiliation:Siemens AG
Submitted:2020-06-02