Standard:IEEE 802.1AS-2020Clause:Figure 11-6 and Figure 11-7
Clause title:MDSyncReceiveSM / MDSyncSendSM state machine
Rationale for revision
In Figure 11-6 (1 occurrence) and Figure 11-7 (3 occurrences) a variable portrEnabledOper is referenced. This is nowhere defined. Most likely this should be portOper like in other conditions on the same Figures and is a left-over from an intermediate working version of the standard.
Proposed text
Replace "portEnabledOper" with "portOper" in both Figures
Impact on existing networks
None
Originator
Name:Martin OstertagEmail:martin.ostertag@zhaw.ch
Affiliation:ZHAW Zurich University of Applied Sciences
Submitted:2021-02-02