802.1 Tools
  • Home
  • Maintenance
    • All items
    • Open items
    • Closed items
    • Items for review
    • Status
  • Meetings
  • Help
  • Log in
  1. Maintenance Items
  2. 0307
  3. Request
Requested revision
Standard:IEEE 802.1AS-2020Clause:Figure 11-6 and Figure 11-7
Clause title:MDSyncReceiveSM / MDSyncSendSM state machine
Rationale for revision
In Figure 11-6 (1 occurrence) and Figure 11-7 (3 occurrences) a

variable portrEnabledOper is referenced. This is nowhere

defined. Most likely this should be portOper like in other

conditions on the same Figures and is a left-over from

an intermediate working version of the standard.
Proposed text
Replace "portEnabledOper" with "portOper" in both Figures
Impact on existing networks
None
Originator
Name:Martin OstertagEmail:martin.ostertag@zhaw.ch
Affiliation:ZHAW Zurich University of Applied Sciences
Submitted:2021-02-02