802.1 Tools
  • Home
  • Maintenance
    • All items
    • Open items
    • Closed items
    • Items for review
    • Status
  • Meetings
  • Help
  • Log in
Requested revision
Standard:802.1QClause:A.14 (PICS)
Clause title:Bridge management
Rationale for revision
A.14 ‘Bridge management’ includes items: — MGT-208 ‘PFC entities’, status ‘PFC:O’, i.e. optional conditional on the A.5 PFC item, with reference 12.22.6 — which is the ‘SRP Stream Preload Table’. This is the only occurrence of ‘PFC entities’ in 802.1Q. — MGT-209 ‘ETS Control Entities’, status ‘ETS:M’, with reference 12.24 — which is ‘1:1 PBB-TE IPS managed objects’. This is the only occurrence of ‘ETS Control Entities’ in 802.1Q. — MGT-210 ‘PFC Control Entities’, status ‘PFC:M’, with reference 12.22.6 (see above). This is the only occurrence of ‘PFC Control Entities’ in 802.1Q. I have checked prior 802.1Q amendments and revisions for the above A.14 entry references back to their introduction in 802.1Qaz and could find no time where they pointed to relevant text. [The above detail has been extracted, with minor revision, from https://www.ieee802.org/1/files/public/docs2024/dt-seaman-pfc-management-0924-v02.pdf, discussed by the 802.1 Security Task Group during the September 2024 Interim Meeting as part of P802.1Qdt development.]
Proposed text
Remove MGT-208, MGT-209, MGT-210 from the PICS. I believe this change could be included in 802.1Q-2022-Rev.
Impact on existing networks
Since all the references in these PICS items are incorrect/irrelevant/non-existent there should be no impact on existing networks.
Originator
Name:Mick SeamanEmail:mickseaman@gmail.com
Affiliation:Mick Seaman
Submitted:2024-11-02