Standard:802.1Q-2022Clause:48.6.4
Clause title:The ieee802-dot1q-bridge YANG module
Rationale for revision
In the YANG module, the bridge address is read-write and mandatory. This forces a config model to explicitly configure a globally unique MAC address for the bridge. Historically the bridge address is a read-only value allocated by the manufacturer and embedded in the bridge. The proposed change makes the address read-write, but mandatory-false, which allows a config model to provide an address but does not require it. Not specifying an address in the config model allows the bridge to use the address provided by the manufacturer.
Proposed text
1) Delete the "unique address" statement in a bridge entry in the bridges list. 2) Delete the "mandatory true" statement in the address leaf in the bridge entry in the bridges list.
Impact on existing networks
No impact on existing networks, or existing bridge YANG config files.
Originator
Name:Stephen HaddockEmail:shaddock@stanfordalumni.org
Affiliation:Stephen Haddock Consulting LLC
Submitted:2024-11-12