Requested revision
Standard: | 802.1Q | Clause: | 48.6.4 |
Clause title: | The ieee802-dot1q-bridge YANG module |
Rationale for revision
A wrong description in the node ieee-dot1q-bridge/bridges/bridge/filtering-database/filtering-entry is misleading if someone tries to understand the YANG module reading the descriptions
Proposed text
Change the description from "Information for the entries associated with the Permanent Database." to "Information for the entries associated with the Filtering Database."
Impact on existing networks
The change is backward compatible.
Originator
Name: | Martin Mittelberger | Email: | martin.mittelberger@siemens.com |
Affiliation: | Siemens AG | ||
Submitted: | 2024-11-13 |