  1. Maintenance Items
  2. 0286
  3. Request
Requested revision
Standard:802.1Q-2018Clause:8.6.9.2
Clause title:List Execute state machine
Rationale for revision
The state machine in Figure 8-17 has no defined outcome if OperControlListLength = 0.
Proposed text
Add transition from NEW_CYCLE to END_OF_CYCLE under the condition (OperControlListLength == 0).

Note, that this transition ensures, that no changes are made on the gate states.
Impact on existing networks
There might be implementations that have defined a different behavior if OperControlListLength = 0.
Originator
Name:Marina GutierrezEmail:marina.gutierrez@tttech.com<mailto:marina.gutierrez@tttech.com>
Affiliation:TTTech Computertechnik AG
Submitted:2020-10-20