Minutes for 0187: 802.1Q Port counter for FCS errors

Standard: 802.1BA Clause: 12.6.1.1.3 Draft with fix: Status: Rejected
Submitter: Tom McBeath Date: 2017-06-24 Rationale: When a network is time sensitive it would be helpful to be able to monit...
Show Request Show Preformatted Request
Date Meeting Text Status
2017-06-24 27 Jun 2017 Concall Received
2017-06-27 27 Jun 2017 Concall We need to draw the attention of users of TSN networks that they have to be aware of the error rate on the links they are using. This would make sense as part of 802.1BA or a similar profile of 802.1Q for TSN. Complete then Ballot
2017-07-11 Jul 2017 Plenary This error counter is already available in the managed objects defined in 802.3. Rejected