0293 Approved 2020-10-29 IEEE Std 802.1AS-2020 10.3.17.3 LogAnnounceInterval needs to be logAnnounceInterval ASdm/d0.2
0292 Approved 2020-10-29 IEEE Std 802.1AS-2020 3.23 gPTP Communication Path should be gPTP communication path ASdm/d0.2
0291 Published
Closed
2020-10-29 IEEE Std 802.1AS-2020 16.5.3.2.2 Improperly named field rxTime of CSN TLV AS-2020/Cor1/d1.0
0290 Published
Closed
2020-10-29 IEEE Std 802.1AS-2020 12.5.1.2 Incorrect details in NOTE on burstDuration calculation AS-2020/Cor1/d1.0
0289 Approved 2020-10-29 IEEE Std 802.1AS-2020 10.3 Several references to 11.2.13 need to be removed ASdm/d0.2
0288 Published
Closed
2020-10-29 IEEE Std 802.1AS-2020 10.2.1, 11.2.1 syncSequenceId is wrong state machine blocks AS-2020/Cor1/d1.0
0305 Withdrawn
Closed
2020-11-23 IEEE Std 802.1AB-2016 6.7 MAC address requirements of LLDP
0287 Approved 2020-10-27 IEEE Std 802 2 Update IEEE Std 802 to reflect withdrawal of IEEE Std 802.1D 802f/d0.4
0301 Withdrawn
Closed
2020-11-05 IEEE 802.1Q-2018 17.7.4 ieee8021QBridgeStaticUnicastReceivePort and ieee8021QBridgeStaticMulticastReceivePort Qcw/d2.0
0251 Published
Closed
2020-01-14 802.1Q-2018 8.6.5.1 802.1Q-2018 Figure 8-13 missing stream_handle 802.1Qcr/D2.2