2 Dec 2020 Concall Meeting
Location: WebEx | Minutes | |
Number | Status | Submitted | Standard | Clause | Subject | Draft | |||
---|---|---|---|---|---|---|---|---|---|
0289 | Approved | 2020-10-29 | IEEE Std 802.1AS-2020 | 10.3 | Several references to 11.2.13 need to be removed | ASdm/d0.2 | |||
0278 | Approved | 2020-08-11 | 802.1AS-2020 | 5.4.2 | Inconsistent Clause 5 and PICS with respect to state machines | ASdm/d0.5 | |||
0299 | Published
Closed |
2020-11-05 | 802.1BA-2011 | 5 | Remove 802.1D references from 802.1BA | BA-Rev/d1.0 | |||
0300 | Rejected
Closed |
2020-11-05 | 802.1BR-201R | 6.10.1 | Remove 802.1D references from 802.1BR | BR-Rev/d?.? | |||
0285 | Published
Closed |
2020-10-13 | 802.1CB-2017 | 10.4.1.4 | 802.1CB-2017 10.4.1.4 frerSeqRcvyReset | CBdb/D1.1 | |||
0304 | Approved | 2020-11-16 | IEEE Std 802.1Q-2018 | 17.7.1 | IEEE8021PriorityCodePoint misnamed | Qcw/d1.5 | |||
0301 | Withdrawn
Closed |
2020-11-05 | IEEE 802.1Q-2018 | 17.7.4 | ieee8021QBridgeStaticUnicastReceivePort and ieee8021QBridgeStaticMulticastReceivePort | Qcw/d2.0 | |||
0286 | Published
Closed |
2020-10-20 | 802.1Q-2018 | 8.6.9.2 | List Execute state machine | Q-Rev/D0.5 | |||
0305 | Withdrawn
Closed |
2020-11-23 | IEEE Std 802.1AB-2016 | 6.7 | MAC address requirements of LLDP |